{"id":110925,"date":"2024-09-19T19:09:18","date_gmt":"2024-09-19T17:09:18","guid":{"rendered":"https:\/\/batijournal.com\/?p=110925"},"modified":"2024-09-19T19:09:18","modified_gmt":"2024-09-19T17:09:18","slug":"nouvelle-generation-de-rupteurs-de-ponts-thermiques","status":"publish","type":"post","link":"https:\/\/batijournal.com\/index.php\/nouvelle-generation-de-rupteurs-de-ponts-thermiques\/110925\/","title":{"rendered":"Nouvelle g\u00e9n\u00e9ration de rupteurs de ponts thermiques"},"content":{"rendered":"<p>Sch\u00f6ck a am\u00e9lior\u00e9 la performance thermique des mod\u00e8les Sch\u00f6ck Rutherma DF\/DFi, d\u00e9di\u00e9s au traitement des ponts thermiques entre la dalle et la fa\u00e7ade dans le cadre d\u2019une ITI, avec une valeur psi pass\u00e9e de 0.13 \u00e0 0.10.<\/p>\n<p>Au c\u0153ur des rupteurs Sch\u00f6ck Rutherma DF\/DFi nouvelle g\u00e9n\u00e9ration, perdurent le corps de l\u2019isolant, toujours en N\u00e9opor\u00ae (polystyr\u00e8ne graphit\u00e9), de m\u00eame que les boucles de tranchant, pour la capacit\u00e9 portante verticale. Les \u00e9volutions apport\u00e9es concernent tout d\u2019abord les boucles de moment, reprenant le moment fl\u00e9chissant sur l\u2019appui au niveau du rupteur, dont le diam\u00e8tre de la partie en inox a \u00e9t\u00e9 r\u00e9duit, de fa\u00e7on \u00e0 restreindre les ponts thermiques entre l\u2019ext\u00e9rieur (la fa\u00e7ade) et l\u2019int\u00e9rieur (la dalle). En effet, ces \u00e9l\u00e9ments traversants en acier occasionnent de petites conductions thermiques : de facto, en diminuer le diam\u00e8tre induit de moindres conductions. De m\u00eame, les plaques coupe-feu, en parties inf\u00e9rieure et sup\u00e9rieure du rupteur, initialement en silico calcaire, ont \u00e9t\u00e9 remplac\u00e9es par des bandes de laine min\u00e9rale prot\u00e9g\u00e9es par un profil\u00e9 en PVC, offrant une r\u00e9sistance au feu optimale, la performance d\u2019isolation thermique de la laine min\u00e9rale \u00e9tant, par ailleurs, sup\u00e9rieure \u00e0 celle de la plaque silico calcaire. Toujours \u00e0 l\u2019\u00e9coute des remont\u00e9es terrain, Sch\u00f6ck en a profit\u00e9 pour que ces plaques coupe-feu, auparavant d\u00e9bordantes sur les c\u00f4t\u00e9s, soient d\u00e9sormais affleurantes afin de faciliter la mise en \u0153uvre. Ces deux modifications, sans surco\u00fbt, ont permis d\u2019am\u00e9liorer la performance d\u2019isolation thermique du produit, qui est donc pass\u00e9 d\u2019une valeur Psi de 0.13 \u00e0 0.10, meilleure valeur actuelle du march\u00e9. Autre \u00e9volution int\u00e9ressante, le PV feu ne rend plus n\u00e9cessaire de faire passer les aciers filants du cha\u00eenage du voile dans les boucles du rupteur Sch\u00f6ck Rutherma DF\/DFi, ce qui facilite la mise en place du produit dans le coffrage.<\/p>\n<p>Sch\u00f6ck lance \u00e9galement une version antisismique, Sch\u00f6ck Rutherma DF-S\/DFi-S, sous ATEx valid\u00e9e par le CSTB le 31 mai dernier : une solution pr\u00eate \u00e0 l\u2019emploi (sans aucun module additionnel et sans ferraillage compl\u00e9mentaire sp\u00e9cifique \u00e0 pr\u00e9voir), simple et rapide \u00e0 mettre en \u0153uvre, permettant de traiter tous les projets soumis aux exigences parasismiques en ITI en France m\u00e9tropolitaine.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Sch\u00f6ck a am\u00e9lior\u00e9 la performance thermique des mod\u00e8les Sch\u00f6ck Rutherma DF\/DFi, d\u00e9di\u00e9s au traitement des ponts thermiques entre la dalle et la fa\u00e7ade dans le cadre d\u2019une ITI, avec une valeur psi pass\u00e9e de 0.13 \u00e0 0.10. Au c\u0153ur des rupteurs Sch\u00f6ck Rutherma DF\/DFi nouvelle g\u00e9n\u00e9ration, perdurent le corps de l\u2019isolant, toujours en N\u00e9opor\u00ae (polystyr\u00e8ne [&hellip;]<\/p>\n","protected":false},"author":17,"featured_media":110926,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_et_pb_use_builder":"","_et_pb_old_content":"","_et_gb_content_width":"","footnotes":""},"categories":[6356,10771,10774],"tags":[6423],"class_list":["post-110925","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-produits-solutions-techniques","category-5facades","category-produits-5facades","tag-rupteur-thermique"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Nouvelle g\u00e9n\u00e9ration de rupteurs de ponts thermiques<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/batijournal.com\/index.php\/nouvelle-generation-de-rupteurs-de-ponts-thermiques\/110925\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Nouvelle g\u00e9n\u00e9ration de rupteurs de ponts thermiques\" \/>\n<meta property=\"og:description\" content=\"Sch\u00f6ck a am\u00e9lior\u00e9 la performance thermique des mod\u00e8les Sch\u00f6ck Rutherma DF\/DFi, d\u00e9di\u00e9s au traitement des ponts thermiques entre la dalle et la fa\u00e7ade dans le cadre d\u2019une ITI, avec une valeur psi pass\u00e9e de 0.13 \u00e0 0.10. Au c\u0153ur des rupteurs Sch\u00f6ck Rutherma DF\/DFi nouvelle g\u00e9n\u00e9ration, perdurent le corps de l\u2019isolant, toujours en N\u00e9opor\u00ae (polystyr\u00e8ne [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/batijournal.com\/index.php\/nouvelle-generation-de-rupteurs-de-ponts-thermiques\/110925\/\" \/>\n<meta property=\"og:site_name\" content=\"Batijournal\" \/>\n<meta property=\"article:published_time\" content=\"2024-09-19T17:09:18+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/batijournal.com\/wp-content\/uploads\/2024\/09\/2_SCHOCK-RUTHERMADF.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"567\" \/>\n\t<meta property=\"og:image:height\" content=\"319\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"St\u00e9phane Miget\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@bati_journal\" \/>\n<meta name=\"twitter:site\" content=\"@bati_journal\" \/>\n<meta name=\"twitter:label1\" content=\"\u00c9crit par\" \/>\n\t<meta name=\"twitter:data1\" content=\"St\u00e9phane Miget\" \/>\n\t<meta name=\"twitter:label2\" content=\"Dur\u00e9e de lecture estim\u00e9e\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/batijournal.com\\\/index.php\\\/nouvelle-generation-de-rupteurs-de-ponts-thermiques\\\/110925\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/batijournal.com\\\/index.php\\\/nouvelle-generation-de-rupteurs-de-ponts-thermiques\\\/110925\\\/\"},\"author\":{\"name\":\"St\u00e9phane Miget\",\"@id\":\"https:\\\/\\\/batijournal.com\\\/#\\\/schema\\\/person\\\/1dc96ec6957aa1ccb25ebe78bb19f100\"},\"headline\":\"Nouvelle g\u00e9n\u00e9ration de rupteurs de ponts thermiques\",\"datePublished\":\"2024-09-19T17:09:18+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/batijournal.com\\\/index.php\\\/nouvelle-generation-de-rupteurs-de-ponts-thermiques\\\/110925\\\/\"},\"wordCount\":416,\"image\":{\"@id\":\"https:\\\/\\\/batijournal.com\\\/index.php\\\/nouvelle-generation-de-rupteurs-de-ponts-thermiques\\\/110925\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/batijournal.com\\\/wp-content\\\/uploads\\\/2024\\\/09\\\/2_SCHOCK-RUTHERMADF.jpg\",\"keywords\":[\"rupteur thermique\"],\"articleSection\":[\"Produits &amp; Solutions techniques\",\"zz_5fa\u00e7ades\",\"zz_Nouveaut\u00e9s Produits - 5fa\u00e7ades\"],\"inLanguage\":\"fr-FR\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/batijournal.com\\\/index.php\\\/nouvelle-generation-de-rupteurs-de-ponts-thermiques\\\/110925\\\/\",\"url\":\"https:\\\/\\\/batijournal.com\\\/index.php\\\/nouvelle-generation-de-rupteurs-de-ponts-thermiques\\\/110925\\\/\",\"name\":\"Nouvelle g\u00e9n\u00e9ration de rupteurs de ponts thermiques\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/batijournal.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/batijournal.com\\\/index.php\\\/nouvelle-generation-de-rupteurs-de-ponts-thermiques\\\/110925\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/batijournal.com\\\/index.php\\\/nouvelle-generation-de-rupteurs-de-ponts-thermiques\\\/110925\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/batijournal.com\\\/wp-content\\\/uploads\\\/2024\\\/09\\\/2_SCHOCK-RUTHERMADF.jpg\",\"datePublished\":\"2024-09-19T17:09:18+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/batijournal.com\\\/#\\\/schema\\\/person\\\/1dc96ec6957aa1ccb25ebe78bb19f100\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/batijournal.com\\\/index.php\\\/nouvelle-generation-de-rupteurs-de-ponts-thermiques\\\/110925\\\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/batijournal.com\\\/index.php\\\/nouvelle-generation-de-rupteurs-de-ponts-thermiques\\\/110925\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/batijournal.com\\\/index.php\\\/nouvelle-generation-de-rupteurs-de-ponts-thermiques\\\/110925\\\/#primaryimage\",\"url\":\"https:\\\/\\\/batijournal.com\\\/wp-content\\\/uploads\\\/2024\\\/09\\\/2_SCHOCK-RUTHERMADF.jpg\",\"contentUrl\":\"https:\\\/\\\/batijournal.com\\\/wp-content\\\/uploads\\\/2024\\\/09\\\/2_SCHOCK-RUTHERMADF.jpg\",\"width\":567,\"height\":319},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/batijournal.com\\\/index.php\\\/nouvelle-generation-de-rupteurs-de-ponts-thermiques\\\/110925\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Accueil\",\"item\":\"https:\\\/\\\/batijournal.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Produits &amp; Solutions techniques\",\"item\":\"https:\\\/\\\/batijournal.com\\\/index.php\\\/category\\\/produits-solutions-techniques\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Nouvelle g\u00e9n\u00e9ration de rupteurs de ponts thermiques\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/batijournal.com\\\/#website\",\"url\":\"https:\\\/\\\/batijournal.com\\\/\",\"name\":\"Batijournal\",\"description\":\"L&#039;actualit\u00e9 du b\u00e2timent\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/batijournal.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/batijournal.com\\\/#\\\/schema\\\/person\\\/1dc96ec6957aa1ccb25ebe78bb19f100\",\"name\":\"St\u00e9phane Miget\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/89915563d925342126b8ef0281b93d9d7fc337043e8df017f780908eb9644451?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/89915563d925342126b8ef0281b93d9d7fc337043e8df017f780908eb9644451?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/89915563d925342126b8ef0281b93d9d7fc337043e8df017f780908eb9644451?s=96&d=mm&r=g\",\"caption\":\"St\u00e9phane Miget\"},\"url\":\"https:\\\/\\\/batijournal.com\\\/index.php\\\/author\\\/stephane\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Nouvelle g\u00e9n\u00e9ration de rupteurs de ponts thermiques","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/batijournal.com\/index.php\/nouvelle-generation-de-rupteurs-de-ponts-thermiques\/110925\/","og_locale":"fr_FR","og_type":"article","og_title":"Nouvelle g\u00e9n\u00e9ration de rupteurs de ponts thermiques","og_description":"Sch\u00f6ck a am\u00e9lior\u00e9 la performance thermique des mod\u00e8les Sch\u00f6ck Rutherma DF\/DFi, d\u00e9di\u00e9s au traitement des ponts thermiques entre la dalle et la fa\u00e7ade dans le cadre d\u2019une ITI, avec une valeur psi pass\u00e9e de 0.13 \u00e0 0.10. Au c\u0153ur des rupteurs Sch\u00f6ck Rutherma DF\/DFi nouvelle g\u00e9n\u00e9ration, perdurent le corps de l\u2019isolant, toujours en N\u00e9opor\u00ae (polystyr\u00e8ne [&hellip;]","og_url":"https:\/\/batijournal.com\/index.php\/nouvelle-generation-de-rupteurs-de-ponts-thermiques\/110925\/","og_site_name":"Batijournal","article_published_time":"2024-09-19T17:09:18+00:00","og_image":[{"width":567,"height":319,"url":"https:\/\/batijournal.com\/wp-content\/uploads\/2024\/09\/2_SCHOCK-RUTHERMADF.jpg","type":"image\/jpeg"}],"author":"St\u00e9phane Miget","twitter_card":"summary_large_image","twitter_creator":"@bati_journal","twitter_site":"@bati_journal","twitter_misc":{"\u00c9crit par":"St\u00e9phane Miget","Dur\u00e9e de lecture estim\u00e9e":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/batijournal.com\/index.php\/nouvelle-generation-de-rupteurs-de-ponts-thermiques\/110925\/#article","isPartOf":{"@id":"https:\/\/batijournal.com\/index.php\/nouvelle-generation-de-rupteurs-de-ponts-thermiques\/110925\/"},"author":{"name":"St\u00e9phane Miget","@id":"https:\/\/batijournal.com\/#\/schema\/person\/1dc96ec6957aa1ccb25ebe78bb19f100"},"headline":"Nouvelle g\u00e9n\u00e9ration de rupteurs de ponts thermiques","datePublished":"2024-09-19T17:09:18+00:00","mainEntityOfPage":{"@id":"https:\/\/batijournal.com\/index.php\/nouvelle-generation-de-rupteurs-de-ponts-thermiques\/110925\/"},"wordCount":416,"image":{"@id":"https:\/\/batijournal.com\/index.php\/nouvelle-generation-de-rupteurs-de-ponts-thermiques\/110925\/#primaryimage"},"thumbnailUrl":"https:\/\/batijournal.com\/wp-content\/uploads\/2024\/09\/2_SCHOCK-RUTHERMADF.jpg","keywords":["rupteur thermique"],"articleSection":["Produits &amp; Solutions techniques","zz_5fa\u00e7ades","zz_Nouveaut\u00e9s Produits - 5fa\u00e7ades"],"inLanguage":"fr-FR"},{"@type":"WebPage","@id":"https:\/\/batijournal.com\/index.php\/nouvelle-generation-de-rupteurs-de-ponts-thermiques\/110925\/","url":"https:\/\/batijournal.com\/index.php\/nouvelle-generation-de-rupteurs-de-ponts-thermiques\/110925\/","name":"Nouvelle g\u00e9n\u00e9ration de rupteurs de ponts thermiques","isPartOf":{"@id":"https:\/\/batijournal.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/batijournal.com\/index.php\/nouvelle-generation-de-rupteurs-de-ponts-thermiques\/110925\/#primaryimage"},"image":{"@id":"https:\/\/batijournal.com\/index.php\/nouvelle-generation-de-rupteurs-de-ponts-thermiques\/110925\/#primaryimage"},"thumbnailUrl":"https:\/\/batijournal.com\/wp-content\/uploads\/2024\/09\/2_SCHOCK-RUTHERMADF.jpg","datePublished":"2024-09-19T17:09:18+00:00","author":{"@id":"https:\/\/batijournal.com\/#\/schema\/person\/1dc96ec6957aa1ccb25ebe78bb19f100"},"breadcrumb":{"@id":"https:\/\/batijournal.com\/index.php\/nouvelle-generation-de-rupteurs-de-ponts-thermiques\/110925\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/batijournal.com\/index.php\/nouvelle-generation-de-rupteurs-de-ponts-thermiques\/110925\/"]}]},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/batijournal.com\/index.php\/nouvelle-generation-de-rupteurs-de-ponts-thermiques\/110925\/#primaryimage","url":"https:\/\/batijournal.com\/wp-content\/uploads\/2024\/09\/2_SCHOCK-RUTHERMADF.jpg","contentUrl":"https:\/\/batijournal.com\/wp-content\/uploads\/2024\/09\/2_SCHOCK-RUTHERMADF.jpg","width":567,"height":319},{"@type":"BreadcrumbList","@id":"https:\/\/batijournal.com\/index.php\/nouvelle-generation-de-rupteurs-de-ponts-thermiques\/110925\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Accueil","item":"https:\/\/batijournal.com\/"},{"@type":"ListItem","position":2,"name":"Produits &amp; Solutions techniques","item":"https:\/\/batijournal.com\/index.php\/category\/produits-solutions-techniques\/"},{"@type":"ListItem","position":3,"name":"Nouvelle g\u00e9n\u00e9ration de rupteurs de ponts thermiques"}]},{"@type":"WebSite","@id":"https:\/\/batijournal.com\/#website","url":"https:\/\/batijournal.com\/","name":"Batijournal","description":"L&#039;actualit\u00e9 du b\u00e2timent","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/batijournal.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"},{"@type":"Person","@id":"https:\/\/batijournal.com\/#\/schema\/person\/1dc96ec6957aa1ccb25ebe78bb19f100","name":"St\u00e9phane Miget","image":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/secure.gravatar.com\/avatar\/89915563d925342126b8ef0281b93d9d7fc337043e8df017f780908eb9644451?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/89915563d925342126b8ef0281b93d9d7fc337043e8df017f780908eb9644451?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/89915563d925342126b8ef0281b93d9d7fc337043e8df017f780908eb9644451?s=96&d=mm&r=g","caption":"St\u00e9phane Miget"},"url":"https:\/\/batijournal.com\/index.php\/author\/stephane\/"}]}},"_links":{"self":[{"href":"https:\/\/batijournal.com\/index.php\/wp-json\/wp\/v2\/posts\/110925","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/batijournal.com\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/batijournal.com\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/batijournal.com\/index.php\/wp-json\/wp\/v2\/users\/17"}],"replies":[{"embeddable":true,"href":"https:\/\/batijournal.com\/index.php\/wp-json\/wp\/v2\/comments?post=110925"}],"version-history":[{"count":0,"href":"https:\/\/batijournal.com\/index.php\/wp-json\/wp\/v2\/posts\/110925\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/batijournal.com\/index.php\/wp-json\/wp\/v2\/media\/110926"}],"wp:attachment":[{"href":"https:\/\/batijournal.com\/index.php\/wp-json\/wp\/v2\/media?parent=110925"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/batijournal.com\/index.php\/wp-json\/wp\/v2\/categories?post=110925"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/batijournal.com\/index.php\/wp-json\/wp\/v2\/tags?post=110925"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}